Topic : | HPSBMA02362 SSRT080044, SSRT080045 rev.1 - HP OpenView Network Node Manager (OV
|
SecurityAlert : 4209
CVE : CVE-2008-3536 CVE : CVE-2008-3537 CWE : CWE-NOMAPPING
CWE : CWE-NOMAPPING
SecurityRisk : High (About)
Remote Exploit : Yes
Local Exploit : No
Victim interaction required : No
Exploit Available : No
Credit : HP Software Security Response Team
Published : 04.09.2008
Affected Software : | HP, OpenView Network Node Manager, 7.01
HP, OpenView Network Node Manager, 7.51
HP, OpenView Network Node Manager, 7.53 |
 Advisory Content : -----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
SUPPORT COMMUNICATION - SECURITY BULLETIN
Document ID: c01537275
Version: 1
HPSBMA02362 SSRT080044, SSRT080045 rev.1 - HP OpenView Network Node Manager
(OV NNM),Remote Denial of Service (DoS)
NOTICE: The information in this Security Bulletin should be acted upon as
soon aspossible.
Release Date: 2008-09-02
Last Updated: 2008-09-02
Potential Security Impact: Remote Denial of Service (DoS)
Source: Hewlett-Packard Company, HP Software Security Response Team
VULNERABILITY SUMMARY
Potential vulnerabilities have been identified with HP OpenView Network
Node Manager(OV NNM). The vulnerabilities could be exploited remotely to
create a Denial ofService (DoS).
References: CVE-2008-3536, CVE-2008-3537
SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed.
HP OpenView Network Node Manager (OV NNM) v7.01, v7.51, v7.53 running on
HP-UX,Linux, Solaris, and Windows
BACKGROUND
CVSS 2.0 Base Metrics
===============================================
Reference Base Vector Base Score
CVE-2008-3536 (AV:N/AC:L/Au:N/C:N/I:N/A:C) 7.8
CVE-2008-3537 (AV:N/AC:L/Au:N/C:N/I:N/A:C) 7.8
===============================================
Information on CVSS is documented in HP Customer Notice: HPSN-2008-002.
RESOLUTION
HP has made a new version of the ovalarmsrv program available to resolve
thevulnerabilities. The new ovalarmsrv is available as a file to be
installed manually.There are separate ovalarmsrv files for each version of
NNM. The files are listed inthe table below. Instructions for installing
the files are contained in thereadme_for_ovalarmsrv.txt file.
For NNM v7.01 and NNM v7.51 patches must be installed before the ovalarmsrv
file isinstalled. No patches are required for NNM v7.53.
The ovalarmsrv files and the readme_for_ovalarmsrv.txt file are available
fromftp://ss080044:ss080044@hprc.external.hp.com/
The patches are available from http://itrc.hp.com
Instructions for installing the files are contained in the
readme_for_ovalarmsrv.txtfile.
Instruction File - readme_for_ovalarmsrv.txt
MD5 Sum - 8b0cf8a7fd2e0d1dcdc6fe91047fad19
OV NNM v7.53
=======================
Operating_System - HP-UX (IA)
Required_Patch - No patch to base NNM v7.53 is required
File - 753_HP-UX_IA_ovalarmsrv
File MD5 Sum - 9fcaebbd9dcd25673a09a03c742f4260
Operating_System - HP-UX (PA)
Required_Patch - No patch to base NNM v7.53 is required
File - 753_HP-UX_PA_ovalarmsrv
File MD5 Sum - f4f2147d47cc7809a38d550ebe75952c
Operating_System - Linux RedHatAS2.1
Required_Patch - No patch to base NNM v7.53 is required
File - 753_Linux2.4_ovalarmsrv
File MD5 Sum - 8c6c0d73fa5255e48b9fcc4b242ff7f4
Operating_System - Linux RedHat4AS-x86_64
Required_Patch - No patch to base NNM v7.53 is required
File - 753_Linux2.6_ovalarmsrv
File MD5 Sum - 4a22e7c68b4167316f9d50a7fd7d149b
Operating_System - Solaris
Required_Patch - No patch to base NNM v7.53 is required
File - 753_Solaris_ovalarmsrv
File MD5 Sum - 7d531b1b32d2cab3d4e15c3f4ad25bd5
Operating_System - Windows
Required_Patch - No patch to base NNM v7.53 is required
File - 753_Windows_ovalarmsrv.exe
File MD5 Sum - 8f0aee89dbf29048066d712068109911
OV NNM v7.51
=======================
Operating_System - HP-UX (IA)
Required_Patch - PHSS_37274 or subsequent
File - 751_HP-UX_IA_ovalarmsrv
File MD5 Sum - ac02790b00d271a2be529b6ba240c7cc
Operating_System - HP-UX (PA)
Required_Patch - PHSS_37273 or subsequent
File - 751_HP-UX_PA_ovalarmsrv
File MD5 Sum - f8126883ac5b545c8751aaf8de9f3847
Operating_System - Linux RedHatAS2.1
Required_Patch - LXOV_00060 or subsequent
File - 751_Linux_ovalarmsrv
File MD5 Sum - f852e179a570c15ac2e087b9b37da3fc
Operating_System - Solaris
Required_Patch - PSOV_03490 or subsequent
File - 751_Solaris_ovalarmsrv
File MD5 Sum - 3c8006631a1cbe9bb2bd2d4b9af1ab43
Operating_System - Windows
Required_Patch - NNM_01168 or subsequent
File - 751_Windows_ovalarmsrv.exe
File MD5 Sum - 08063fc2d503963ae3301c960527f9e1
OV NNM v7.01
=======================
Operating_System - HP-UX (PA)
Required_Patch - PHSS_36773 or subsequent
File - 701_HP-UX_ovalarmsrv
File MD5 Sum - d096d44b2ee64754befee36b044db182
Operating_System - Solaris
Required_Patch - PSOV_03480 or subsequent
File - 701_Solaris_ovalarmsrv
File MD5 Sum - 1922add1c5bdb6d6265583f8caac7f28
Operating_System - Windows
Required_Patch - NNM_01159 or subsequent
File - 701_Windows_ovalarmsrv.exe
File MD5 Sum - 0f1dcdabd534691a108bd4de56c17385
MANUAL ACTIONS: Yes - NonUpdate
Apply the appropriate file as described in the Resolution.
PRODUCT SPECIFIC INFORMATION
HP-UX Software Assistant: HP-UX Software Assistant is an enhanced
application thatreplaces HP-UX Security Patch Check. It analyzes all
Security Bulletins issued by HPand lists recommended actions that may apply
to a specific HP-UX system. It can alsodownload patches and create a depot
automatically. For more information seehttps://www.hp.com/go/swa
The following text is for use by the HP-UX Software Assistant.
AFFECTED VERSIONS (for HP-UX)
For HP-UX OV NNM 7.53
HP-UX B.11.31
HP-UX B.11.23 (IA)
=============
OVNNMgr.OVNNM-RUN
action: apply 753_HP-UX_IA_ovalarmsrv
URL: ftp://ss080044:ss080044@hprc.external.hp.com/
HP-UX B.11.23 (PA)
HP-UX B.11.11
HP-UX B.11.00
=============
OVNNMgr.OVNNM-RUN
action: apply 753_HP-UX_PA_ovalarmsrv
URL: ftp://ss080044:ss080044@hprc.external.hp.com/
For HP-UX OV NNM 7.51
HP-UX B.11.31
HP-UX B.11.23 (IA)
=============
OVNNMgr.OVNNM-RUN
action: install PHSS_37274 or subsequent, then apply
751_HP-UX_IA_ovalarmsrv
URL: ftp://ss080044:ss080044@hprc.external.hp.com/
HP-UX B.11.23 (PA)
HP-UX B.11.11
HP-UX B.11.00
=============
OVNNMgr.OVNNM-RUN
action: install PHSS_37273 or subsequent, then apply
751_HP-UX_PA_ovalarmsrv
URL: ftp://ss080044:ss080044@hprc.external.hp.com/
For HP-UX OV NNM 7.01
HP-UX B.11.00
HP-UX B.11.11
=============
OVNNMgr.OVNNM-RUN
action: install PHSS_36773 or subsequent, then apply 701_HP-UX_ovalarmsrv
URL: ftp://ss080044:ss080044@hprc.external.hp.com/
END AFFECTED VERSIONS (for HP-UX)
HISTORY
Version:1 (rev.1) - 2 September 2008 Initial release
Third Party Security Patches: Third party security patches that are to be
installedon systems running HP software products should be applied in
accordance with thecustomer's patch management policy.
Support: For further information, contact normal HP Services support
channel.
Report: To report a potential security vulnerability with any HP supported
product,send Email to: security-alert@hp.com It is strongly recommended
that securityrelated information being communicated to HP be encrypted
using PGP, especiallyexploit information. To get the security-alert PGP
key, please send an e-mailmessage as follows: To: security-alert@hp.com
Subject: get key
Subscribe: To initiate a subscription to receive future HP Security
Bulletins viaEmail:
http://h30046.www3.hp.com/driverAlertProfile.php?regioncode=NA&langcode=USE
NG&jumpid=in_SC-GEN__driverITRC&topiccode=ITRC On the web page: ITRC
security bulletinsand patch sign-up Under Step1: your ITRC security
bulletins and patches
- check ALL categories for which alerts are required and continue.
Under Step2: your ITRC operating systems
- verify your operating system selections are checked and save.
To update an existing subscription: http://h30046.www3.hp.com/subSignIn.php
Log in on the web page: Subscriber's choice for Business: sign-in.
On the web page: Subscriber's Choice: your profile summary - use Edit
Profile toupdate appropriate sections.
To review previously published Security Bulletins
visit:http://www.itrc.hp.com/service/cki/secBullArchive.do
* The Software Product Category that this Security Bulletin relates to is
representedby the 5th and 6th characters of the Bulletin number in the
title:
GN = HP General SW
MA = HP Management Agents
MI = Misc. 3rd Party SW
MP = HP MPE/iX
NS = HP NonStop Servers
OV = HP OpenVMS
PI = HP Printing & Imaging
ST = HP Storage SW
TL = HP Trusted Linux
TU = HP Tru64 UNIX
UX = HP-UX
VV = HP VirtualVault
System management and security procedures must be reviewed frequently to
maintainsystem integrity. HP is continually reviewing and enhancing the
security features ofsoftware products to provide customers with current
secure solutions.
"HP is broadly distributing this Security Bulletin in order to bring to the
attentionof users of the affected HP products the important security
information contained inthis Bulletin. HP recommends that all users
determine the applicability of thisinformation to their individual
situations and take appropriate action. HP does notwarrant that this
information is necessarily accurate or complete for all usersituations and,
consequently, HP will not be responsible for any damages resultingfrom
user's use or disregard of the information provided in this Bulletin. To
theextent permitted by law, HP disclaims all warranties, either express or
implied,including the warranties of merchantability and fitness for a
particular purpose,title and non-infringement."
©Copyright 2008 Hewlett-Packard Development Company, L.P.
Hewlett-Packard Company shall not be liable for technical or editorial
errors oromissions contained herein. The information provided is provided
"as is" withoutwarranty of any kind. To the extent permitted by law,
neither HP or its affiliates,subcontractors or suppliers will be liable for
incidental, special or consequentialdamages including downtime cost; lost
profits; damages relating to the procurement ofsubstitute products or
services; or damages for loss of data, or softwarerestoration. The
information in this document is subject to change without
notice.Hewlett-Packard Company and the names of Hewlett-Packard products
referenced hereinare trademarks of Hewlett-Packard Company in the United
States and other countries.Other product and company names mentioned herein
may be trademarks of their respective owners.
-----BEGIN PGP SIGNATURE-----
Version: PGP 8.1
iQA/AwUBSL073+AfOvwtKn1ZEQJcxgCg0aJEGojYHwVUzL1bivwhFn6SzakAmgLV
PaW1PVmyTp72LzxgUvgkg3nX
=VrHR
-----END PGP SIGNATURE-----
References :
http://marc.info/?l=bugtraq&m=122037165310549&w=2
Feedback :
If you have additional information or notice any errors regarding this security advisory, please use contact form or email us at info()securityreason()com.
|
|
|
|